- Fluke 75 Series Ii Multimeter Instructions
- Fluke 70 Series Ii Multimeter Manual
- Fluke Multimeter Manual Free
- Fluke 70 Series Ii Multimeter User Manual Pdf
- Fluke 70 Series Ii
- Fluke 70 Ii Multimeter User Manual
By checking this box, I agree to receive marketing communications and product offers by email from Fluke Electronics Corporation, transacting under Fluke Industrial,. Fluke 73 Pdf User Manuals. View online or download Fluke 73 User Manual. Manuals; Brands; Fluke Manuals; Multimeter; 73; Fluke 73 Manuals Manuals and User Guides for Fluke 73. We have 3 Fluke 73 manuals available for free PDF download: Service Manual. Fluke 70 and 170 Series Digital Multimeter Specifications. This manual presents service information for the Fluke 77 Series III Multimeter. The manual includes a theory of operation, general maintenance procedures, performance tests, calibration procedures, troubleshooting information, a list of replaceable parts, and schematic diagrams. A meter under warranty will be promptly repaired or replaced (at. 70/73 English Instruction Sheet Page 1 ® 70/73 Series III Multimeter Instruction Sheet W Read First: Safety Information To ensure that the meter is used safely, follow these instructions:. Never use the meter if the meter or test leads look damaged. Be sure the test leads and rotary switch are in the correct position for the desired.
Advertising
77/75/23/21 English Instruction Sheet
Page
1
®
77/75/23/21
Series III Multimeter
Instruction Sheet
W
Read First: Safety Information
•
Never use the meter if the meter or test leads look damaged.
•
Linksys n300 router review. User Guide Linksys E-Series Routers. E1200 E900 E1500 E2500 E3200 E4200 Linksys E-Series. I Linksys E-Series E900 Contents. How to improve your wireless connection speed.15. Linksys E-Series E1200/E1500 Contents. Linksys E1200 N300 Wireless Router Frequently Asked Questions; Comparison of Linksys routers’ standards and speeds; How to prevent your Linksys router from getting The Moon malware; Introduction to Linksys Connect; Linksys Connect and Network Magic compatibility issues with OS X® Lion 10.7, Mountain Lion 10.8, Mavericks 10.9, Yosemite 10.10.
Be sure the test leads and switch are in the correct position for
the desired measurement.
•
Fluke 75 Series Ii Multimeter Instructions
Never measure resistance in a circuit when power is applied.
•
Never touch the probes to a voltage source when the test
leads are plugged into the 10 A or 300 mA input jack.
•
Never apply more than the rated voltage between any input
jack and earth ground.
•
Be careful when working with voltages above 60 V dc or 30 V
ac rms. Such voltages pose a shock hazard.
•
Keep your fingers behind the finger guards on the test probes
when making measurements.
W
Warning
Kidde Alarms: If you look at the back of the alarm, you will see the name of the product and the model number in bold text below the logo. Firex Alarms: If you look at the back of the alarm, you will see where the text is split into two columns, with text on the left and text on the right. The model is the text on the top of the left hand. View and Download Kidde Fyrnetics Slick 1SFW installer's manual online. Smoke and heat alarm. Fyrnetics Slick 1SFW Smoke Alarm pdf manual download. Also for: Fyrnetics slick 1sfwr, Fyrnetics slick 2sfw, Fyrnetics slick 2sfwr, Fyrnetics slick 3sfw, Fyrnetics slick 3sfwr. Kidde fyrnetics model 1275 manual. Download 180 Kidde Smoke Alarm PDF manuals. User manuals, Kidde Smoke alarm Operating guides and Service manuals. Page 1 For models: 1275H,440381 Smoke and Fire Alarm User’s Guide A.C. Wire-in Single and/or Multiple Station (24 Devices) Ionization Smoke Alarm with 9 Volt Battery Back Up and “HUSH” Control to temporarily silence nuisance alarms. Thank you for purchasing this smoke and fire alarm. It is an important part of your family’s home safety plan. View and Download Kidde Fyrnetics Slick 1SFW owner's manual online. 230V Interconnectable Mains Operated Smoke and Heat alarm. Fyrnetics Slick 1SFW Smoke Alarm pdf manual download. Also for: Fyrnetics slick 1sfwr, Fyrnetics slick 2sfw, Fyrnetics slick 2sfwr, Fyrnetics slick 3sfw.
To avoid false readings, which could lead to
possible electric shock or personal injury, replace
the battery as soon as the battery indicator (
possible electric shock or personal injury, replace
the battery as soon as the battery indicator (
M
)
appears.
Symbols
W
Read First: Safety Information
Y
Dangerous Voltage May Be Present
T
Double Insulation
Overvoltage Installation Category per IEC 1010:
CAT II
CAT III
Fluke 70 Series Ii Multimeter Manual
Typical locations include; main wall outlets,
local appliances, and portable equipment.
local appliances, and portable equipment.
Typical locations include switches in the fixed
installation and equipment for industrial use
permanently connected to the fixed installation.
installation and equipment for industrial use
permanently connected to the fixed installation.
PN 650512 August 1997 Rev.2, 7/98
It can coordinate with a phone by method for Bluetooth, through the Gear 360 Connect application. Samsung gear 360 2016 user manual. In like manner, the contraption packs a dark measure of locally accessible stockpiling.Gear 360 SpecsGear 360 CameraProgramming smart, the pack joins the Gear 360 Gallery, and a seperate remote viewfinder application. The contraption might work with late Galaxy pioneer devices, however until further notice we can simply insist Galaxy S7 closeness.The Gear 360 manual has its own battery, so it doesn't ought to be connected with an external power source.
1997, 1998 Fluke Corporation. All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies
Fluke Multimeter Manual Free
Advertising
This manual is related to the following products:
Table of contents
Popular Brands
Popular manuals
User Manual
Sorry, we do not currently have a manual available for this item.
Request a manual | Submit a manual
Request a manual | Submit a manual
Product description from Fluke:
The model numbers Fluke 73 and 77 are an important part of Fluke’s reputation. In many years of service they have become the preferred models for a large number of professionals. The Fluke 73 and 77 offer exactly the right fit for a wide range of measurements. They are truly all-round performers. The 73 III is perfectly suited for many electronic applications and has the 'classic' 70 series design with removable holster. The 77 III has all the features and functions for a wide range of industrial applications packaged in an ergonomic case with integrated holster. Both models come with the unique lifetime warranty.
Features:
0.3% basic accuracy
3200 count resolution
Digital display with analog bargraph
Manual and automatic ranging
Automatic Touch Hold
Resistance, continuity and diode measurements
Ergonomic case with integrated protective holster (Fluke 77 III)
'Classic' design with removable holster (Fluke 73 III)
Sleep mode preserves battery life
Lifetime warranty
3200 count resolution
Digital display with analog bargraph
Manual and automatic ranging
Automatic Touch Hold
Resistance, continuity and diode measurements
Ergonomic case with integrated protective holster (Fluke 77 III)
'Classic' design with removable holster (Fluke 73 III)
Sleep mode preserves battery life
Lifetime warranty
Specifications:
DC Maximum Voltage:
Fluke 73: 600V
Fluke 77: 1000V
Basic Accuracy: 0.3%
Maximum Resolution: 0.1 mV
AC Maximum Voltage:
Fluke 73: 600V
Fluke 77: 1000V
Basic Accuracy: 2%
Maximum Resolution: 1 mV
DC Maximum Current: 10 A
Maximum Resolution: 0.01 mA
Basic Accuracy: 1.5%
AC Maximum Current: 10 A
Maximum Resolution: 0.01 mA
Basic Accuracy: 2.5%
Max Resistance: 32 M ohm
Basic Accuracy: 0.5%
Maximum Resolution: 0.1 ohm
Fluke 73: 600V
Fluke 77: 1000V
Basic Accuracy: 0.3%
Maximum Resolution: 0.1 mV
AC Maximum Voltage:
Fluke 73: 600V
Fluke 77: 1000V
Basic Accuracy: 2%
Maximum Resolution: 1 mV
DC Maximum Current: 10 A
Maximum Resolution: 0.01 mA
Basic Accuracy: 1.5%
AC Maximum Current: 10 A
Maximum Resolution: 0.01 mA
Basic Accuracy: 2.5%
Max Resistance: 32 M ohm
Basic Accuracy: 0.5%
Maximum Resolution: 0.1 ohm
Fluke 70 Series Ii Multimeter User Manual Pdf
Environmental Specifications
Operating temperature 0°C to +50°C
Storage temperature -40°C to +60°C
Humidity (Without Condensation) 0% - 90% (0°C - 35°C)
0% - 70% (35°C - 50°C)
Operating Altitude 2000 m
Operating temperature 0°C to +50°C
Storage temperature -40°C to +60°C
Humidity (Without Condensation) 0% - 90% (0°C - 35°C)
0% - 70% (35°C - 50°C)
Operating Altitude 2000 m
Fluke 70 Series Ii
Safety Specifications
Overvoltage category Fluke 73 III: EN 61010-1 to 600 V CAT II
Fluke 77 III: EN 61010-1 to 600 V CAT III/1000V CAT II
Agency Approvals UL, CSA, TÜV listed
Overvoltage category Fluke 73 III: EN 61010-1 to 600 V CAT II
Fluke 77 III: EN 61010-1 to 600 V CAT III/1000V CAT II
Agency Approvals UL, CSA, TÜV listed
Fluke 70 Ii Multimeter User Manual
Mechanical & General Specifications
Size Fluke 73 III: 166 x 75 x 28 mm
Fluke 77 III: 190 x 89 37 mm
Weight Fluke 73 III: 340 g
Fluke 77 III: 365 g
Warranty Lifetime
Battery life Alkaline: ~2000 hours typical
Shock & Vibration Per MIL-T-PRF 28800F Class III
Size Fluke 73 III: 166 x 75 x 28 mm
Fluke 77 III: 190 x 89 37 mm
Weight Fluke 73 III: 340 g
Fluke 77 III: 365 g
Warranty Lifetime
Battery life Alkaline: ~2000 hours typical
Shock & Vibration Per MIL-T-PRF 28800F Class III